Menu Side

Welded tubular street lamp bracket posts for in-soil installation – SRsG

 

Technical data
TYPE
H
hd
Ød/DE
Ød1
Ød2
h1
h2
h3
m*
h
 
m
mm
mm
mm
mm
m
m
m
kg
m
S-60SRsG
6,0
400
60/127
89
76
2,2
2,0
2,8 63,3 1,2
S-70SRsG
7,0
400
60/127
89
76
2,2
2,0
3,8 69,1 1,2
S-80SRsG
8,0
600
60/140
89
76
2,5
3,0
3,5 84,3 1,2
S-90SRsG
9,0
600
60/159
114
89 3,0
4,0
3,3 118,6 1,5
S-100SRsG
10,0
600
60/168
114
89 3,5
4,0
4,0 133,3 1,5


Depth “h” of embedding in soil calculated for native soil (with intact structure) and geotechnical parameters from group II
* – Data for single-arm booms
Ød – other mounting diameters must be specified in the inquiry or order
Note: Number of reductions depend on the type of street poles

 

Strength data
TYPE
W
Weight of iluminaires

Wind zone acc, to PN EN 1991-1-4
Permissible surface of luminaires [m2]

MF
 
m
kg
I ≤300 m a.s.l.
I ≤500 m a.s.l.
II ≤300 m a.s.l.
III ≤950 m a.s.l.
kNm
Single-arm boom
1,5
15
0,251 0,156 0,132 0,060 5,0
1,5
15
0,155 0,075 0,055 5,0
1,5
15
0,365 0,217 0,179 0,072 7,5
1,5
15
0,574 0,387 0,341 0,206 12,5
1,5
15
0,530 0,341 0,295 0,163 13,3
Two-arm boom
1,5
15
0,484 0,298 0,250 0,108 5,0
1,5
15
0,290 0,118 0,072 5,0
1,5
15
0,374 0,180 0,132 7,5
1,5
15
0,724 0,452 0,386 0,192 12,5
1,5
15
0,560 0,322 0,266 0,100 13,3

 

Downloadable:

https://elektromontaz.com.pl/storage/image/core_files/2020/6/29/af64ee54fa1bba9d60a641c279426edc/default/preview/Ikony-pdf.jpg Catalog page