Menu Side
Tubular lamp masts
Technical data | |||||||||
TYPE
|
H |
DA/DE
|
H1 |
m
|
n x Øs/A x B
|
Type foundation ring
a x a x h |
|||
m |
mm
|
m |
kg
|
mm
|
m
|
||||
M-140SRw/4 |
14 |
114/205 |
9,0 |
230 |
4 x M24/250×250 |
WF354/4xM24 |
|||
M-160SRw/4 |
16 |
114/205 |
9,0 |
250 |
4 x M24/250×250 |
WF354/4xM24 |
|||
Note: The foundation sizes are preliminary to Group II soils
The foundation construction and mast assembly conditions should be designed in accordance with the documentation for the target location.
The dimensions of the prefabricated foundation block are determined for moderate geotechnical parameters of the soil.
The conditions for prefabricated foundations should be designed in accordance with the construction design and assembly instructions for the lighting mast for the target location.
Strength data
|
||||||
TYPE
|
Weight of iluminaires
|
Wind zone acc, to PN EN 1991-1-4 |
MF
|
|||
kg
|
I≤300 m a.s.l. |
I≤500 m a.s.l. |
II≤300 m a.s.l. |
III≤950 m a.s.l. |
kNm | |
M-140SRw/4 | 100 | 1,035 | 0,623 | 0,456 | 0,346 | 27,5 |
M-160SRw/4 | 100 | 0,600 | 0,306 | 0,200 | 0,140 | 27,5 |
Downloadable:
Catalog page