Technical data | |||||||||||||
TYPE
|
H
|
H1
|
H2
|
H3
|
DA/DE
|
m
|
n x Øs/ØM
|
a x a x h
TYPE |
|||||
m
|
m
|
m
|
m
|
mm
|
kg
|
mm
|
m
|
||||||
M-160K
|
16
|
9,0
|
7,0
|
–
|
200/470
|
761
|
12 x M30/600
|
WF600/12xM30
2,8 x 2,8 x 2,2 |
|||||
M-180K
|
18
|
9,0
|
9,0
|
–
|
200/470
|
833
|
12 x M30/600
|
WF600/12xM30
2,8 x 2,8 x 2,2 |
|||||
M-200K
|
20
|
9,0
|
9,0
|
2,0
|
200/470
|
905
|
12 x M30/600
|
WF600/12xM30
2,8 x 2,8 x 2,2 |
Note: The foundation sizes are preliminary to Group II soils
The higher masts are made in accordance with the PN-EN 1090 standard for individual orders
The foundation construction and mast assembly conditions should be designed in accordance with the documentation for the target location.
The dimensions of the prefabricated foundation block are determined for moderate geotechnical parameters of the soil.
The conditions for prefabricated foundations should be designed in accordance with the construction design and assembly instructions for the lighting mast for the target location.
These masts can be used to illuminate parking lots, sports fields, railway and tram turnouts, etc. At the top of the mast there is a head with a crown left. On the crown can be mounted lighting projectors from different companies, it is recommended to mount 3 or 6 pieces of projectors. Lowering and lifting the crown is carried out manually with a drill with rotation to the right and to the left and a tip that allows insertion on the shaft of the gear. The mast is made of sheet metal bent in a 12-point profile with appropriate ribbing ensuring adequate stiffness and lightness of the structure.
Strength data
|
||||||
TYPE
|
Weight of iluminaires
|
Wind zone acc, to PN EN 1991-1-4 |
MF
|
|||
kg
|
I≤300 m a.s.l. |
I≤500 m a.s.l. |
II≤300 m a.s.l. |
III≤950 m a.s.l. |
kNm | |
M-160K | 200 | 5,291 | 2,911 | 1,781 | 0,971 | 149 |
M-180K | 200 | 3,745 | 1,745 | 0,807 | 0,122 | 149 |
M-200K | 150 | 2,485 | 0,785 | – | – | 149 |